Peak : Peak Finding
===================


.. |pulldown| image:: ../images/pulldown.png
   :align: bottom


.. |check| image:: ../images/check.png
   :align: bottom


.. |radio| image:: ../images/radio.png
   :align: bottom


.. |float| image:: ../images/float.png
   :align: bottom


.. |int| image:: ../images/int.png
   :align: bottom


.. |entry| image:: ../images/entry.png
   :align: bottom


.. |button| image:: ../images/button.png
   :align: bottom


.. |ramp| image:: ../images/ramp.png
   :align: bottom


.. |selector| image:: ../images/selector.png
   :align: bottom


** Peak Settings and Non-Interactive Peak Finding **

The purpose of this dialog is to allow the user to select settings for
finding and integrating peaks, and also to be able to find peaks in an
arbitrary region that is specified in a table rather than via a spectrum
window.

** Find Parameters tab **

This can be used to specify how peak finding works.

First of all, you can search for just positive peaks, just negative
peaks or both, and the default is that it is just positive peaks.
However, this is further filtered by what the contour levels are.
If there are no positive contour levels for a given spectrum then
positive peaks are not found even if this dialog says they can be,
and similarly if there are no negative contour levels for a given
spectrum then negative peaks are not found even if this dialog says
they can be.

The peak finding algorithm looks for local extrema (maximum for
positive peaks and minima for negative peaks).  But on a grid there
are various ways to define what you mean by an extremum.  Suppose
you are trying to determine if point p is a maximum (similar
considerations apply for minimum).  You would want the intensity
at all nearby points to be less than or equal to the intensity at p.
You can just check points that are just +- one point from p in each
dimension, or you can also check "diagonal" points.  For
example, if you are looking at point p = (x, y) in 2D, then the
former would mean checking the four points (x-1, y), (x+1, y)
(x, y-1) and (x, y+1), whereas for the latter you would also have
to check (x-1, y-1), (x-1, y+1), (x+1, y-1) and (x+1, y+1).  In
N dimensions the "diagonal" method involves checking 3^N-1 points
whereas the "non-diagonal" method involves checking only 2N points.
In general the "non-diagonal" method is probably the one to use,
and it is the default.

Peaks are only found above (for positive peaks) or below (for negative
peaks) some threshold.  By default this is determined by the contour level
for the spectrum.  For positive peaks the threshold is the minimum
positive contour level, and for negative peaks the threshold is the
maximum negative contour level.  However these levels can be scaled up
(or down) using the "Scale relative to contour levels" option (default
value 1).  For example, if you have drawn the contour levels low to
show a bit of noise, but do not want the noise picked as peaks, then
you could select a scale of 2 (or whatever) to increase the threshold.

The "Exclusion buffer around peaks" is so that in crowded regions you
do not get too many peaks near one location.  By default the exclusion
buffer is 1 point in each dimension, but this can be increased to make
the algorithm find fewer peaks.

By default the peak finding only looks at the orthogonal region that
is displayed in the given window where peak finding is taking place.
Sometimes it looks like a peak should be found because in x, y you
can see an extremum, but unless it is also an extremum in the orthogonal
dimensions it is not picked.  You can widen out the points being
examined in the orthogonal dimensions by using the "Extra thickness in
orthogonal dims" option, which is specified in points.

The "Minimum drop factor" is by what factor the intensity needs to drop
from its extreme value for there to be considered to be a peak.  This
could help remove sinc wiggle peaks, for example.  The default is that
the drop factor is 0, which in effect means that there is no condition.

The "Volume method" is what is used to estimate the volume of peaks that
are found.  The default is "box sum", which just looks at a fixed size
box around the peak centre and sums the intensities in that.  The size
of the box is set in the table in the Spectrum Widths tab.  The
"truncated box sum" is the same as "box sum" except that the summing
stops in a given direction when (if) the intensities start increasing.
The "parabolic" fit fits a quadratic equation in each dimension to the
intensity at the peak centre and ad +- 1 points and then uses the
equivalent Gaussian fit to estimate the volume.

** Spectrum Widths **

This can be used to specify minimum linewidths (in Hz) for there to be
considered a peak to exist in the peak finding algorithm.  It is also
where the Boxwidth for each dimension in each spectrum is specified.

** Diagonal Exclusions **

This can be used to exclude peaks from being found in regions near
the diagonal (so in homonuclear experiments).  The exclusion region
is specified in ppm and is independent of spectrum.

** Region Peak Find **

This can be used to find peaks non-interactively (so not having to
control shift drag inside a spectrum window).  The region being
analysed is specified in the table.  There are two types of conditions
that can be specified, "include" for regions that should be included
and "exclude" for regions that should be excluded.  The regions are
specified in ppm.

The "Whole Region" button will set the selected row in the table to be
the entire fundamental region of the spectrum.

The "Add Region" button adds an extra row to the table, and the "Delete
Region" button removes the selected row.

The "Adjust Params" button goes to the Find Parameters tab.

The "Find Peaks!" button does the peak finding.



Main Panel
==========

|button| **Clone**: Clone popup window

|button| **Help**: Show popup help document

|button| **Close**: Close popup

Find Parameters
===============

*Documentation missing*

Extrema to search for
~~~~~~~~~~~~~~~~~~~~~


|radio| |radio| ***None***: Sets whether peak picking within spectra find intensity maxima, minima or both maxima and minima

|radio| **positive and negative**: *Documentation missing*

|radio| **positive only**: *Documentation missing*

|radio| **negative only**: *Documentation missing*

Nearby points to check
~~~~~~~~~~~~~~~~~~~~~~


|radio| |radio| ***None***: Sets how permissive the peak picking in when searching for intensity extrema; by adding extra points to the selected search region

|radio| **+-1 in at most one dim**: *Documentation missing*

|radio| **+-1 allowed in any dim**: *Documentation missing*

Other parameters
~~~~~~~~~~~~~~~~


|float| **Scale relative to contour levels**: Threshold above which peaks are picked, relative to the lowest displayed contour; 1.0 means picking exactly what is visible

|int| **Exclusion buffer around peaks (in points)**: The size of the no-pick region, in data points, around existing picked peaks; eliminates duplicate picking

|int| **Extra thickness in orthogonal dims (in points)**: Sets whether to consider any additional planes (Z dimension) when calculating peak volume integrals

|float| **Minimum drop factor (0.0-1.0)**: *Documentation missing*

|pulldown| **Volume method**: Selects which method to use to calculate peak volume integrals when peaks are picked; box sizes are specified in "Spectrum Widths"

Spectrum Widths
===============

*Documentation missing*

|pulldown| **Spectrum**: The spectrum which determines the widths being shown

========================  ================================================================================
**Table 1**
----------------------------------------------------------------------------------------------------------
             *Dimension*  The number of the spectrum dimension to which the settings apply 
               *Isotope*  The nuclear isotope measures in the spectrum dimension 
*Minimum Linewidth (Hz)*  The smallest value for the linewidth of a peak for it to be picked  *(Editable)*
              *Boxwidth*  The size of the spectrum region to perform the volume integral over  *(Editable)*
========================  ================================================================================



Diagonal Exclusions
===================

*Documentation missing*

==========================  ===================================================================================================
**Table 2**
-------------------------------------------------------------------------------------------------------------------------------
                 *Isotope*  The isotope as measures on the axis of a spectrum window 
*Diagonal Exclusion (ppm)*  The distance from the homonuclear diagonal line within which no peak picking can occur  *(Editable)*
==========================  ===================================================================================================



Region Peak Find
================

*Documentation missing*

|pulldown| **Peak List**: Selects which peak list to perform region-wide peak picking for

===========  =======================
**Table 3**
------------------------------------
*Condition*  *Documentation missing* 
===========  =======================



|button| **Whole Region**: Sets the currently selected region row to cover the whole spectrum

|button| **Add Region**: Add a new region row, which may them be set for exclusion or inclusion when peak picking large areas

|button| **Delete Region**: Remove the selected region specification

|button| **Adjust Params**: Go to the panel for setting the parameters that control how peaks extrema are picked